Technical Specification:

Output Sensitivity 1.5 ± 5% mV / V
Zero Output ± 2 % F.S
No-linearity 0.05~0.1 % F.S.
Hysteresis Error 0.03~0.05 % F.S.
Repeatability 0.5 % F.S.
Creep (30min) 0.5 % F.S
Temperature Effect On Output 0.05 % F.S. / 10ºC
Temperature Effect On Zero 0.05 % F.S. / 10ºC
Insulation Resistance =5000MO/100V DC
Reference Excitation Voltage 5~10 V DC/AC
Maximum Excitation Voltage 5 V DC/AC
Compensated temperature range - 10ºC ~ 60 ºC
Operating Temperature - 35 ~ 65 ºC
Safe Load Limit 120 % F.S.
Breaking Load 200 % F.S.
Cable size Ø 2.5~3 × 1000mm
Input Resistance 350 ± 30O
Output Resistance 350 ± 5 O
Protection Class IP67
Connection Type Input: Red (+); Black (-)
Output: Green (+); White: (-)