Brand:RL
Model:-
MOQ:4 Pieces
YAG laser diode driver,YAG LD CW pumped Laser Power Supply, Diode-pumped solid-state laser power supply, DPSSL laser
1. Main Features:
1. Good current soft increasing /decreasing function efficiently avoids laser diode being damaged by inrush current.
2. Extremely small ripple noise effectively protect laser diode from inrush current even when current increase or decrease.
3. Excellent anti-static function efficiently avoid laser diode being damaged by
static electricity.
4. Very good efficiency and perfect open circuit, over current protection and over load protection which makes this power supply has reliable performance.
5. Sensitive water Through detection and water temperature detection keep laser diode in good condition.
6. Instant voltage/current digital indication makes monitoring voltage/current very easy.
7. Internal/external control easily converses internal control of power supply and external control of computer.
8. Standard 2U cabinet lets equipment install very easily.
2.Specification:
Input | Input voltage | AC220V.15% or AC110V.15% (please specify when placing order) | |
AC Frequency | 47---440Hz | ||
Cold inrush current | less than60A(AC220V input) | less than30A(AC110V input) | |
Current Leakage | less than0.7mA(AC220V input) | less than0.4mA(AC110V input) | |
Output | Max Output voltage | DC 24V | |
Voltage ripple noise | less than30mV | ||
Max Output Current | DC 1-30A | ||
Current ripple noise | less than30mA | ||
Temperature drift (Half hour after boot) | less than100ppm/degree | ||
Stability(Half hour after boot) | less than0.1% | ||
Soft increase/decrease time after current starting. | more than10S | ||
Efficiency | more than90%(Full load) | ||
MTBF | more than50000 hours | ||
Withstand Voltage | Inpu-Input,Input-Enclosure:AC1500V 10mA 60s.Output-Enclosue:DC500V 10mA 60s | ||
Protection | Overload circuit, over output overcurrent, overload, water Through detection and water temperature detection | ||
Environment | Operating temperature(-10-40)degree ,Relative humidity:less than90% | ||
Cooling | Force-Air Cooling (FAC) | ||
Dimension | L×W×H=483×88×192 (mm) |