Factory Price Operating Room Equipment Anaesthetic Machine
 
This JINLING-01BII Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and a safety device for preventing cyanosis and necessary alarm system. During the anesthesia, the patient’s respiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.
 
The automatic conversion for standby power while AC power outage, keep working not less than 1 hour
 

Contact Infomation
Send Inquiry
Company name:Wuhan Darppon Medical Technology Co., Ltd
Status:[Offline] [Send message] [Chat]
Business contact:hu (Ms.)
Telphone:
Mobile:
Fax:
Area: Caribbean Region-Bermuda
Address:Room B2713, Optical Valley Time Square, East Lake High Tech
Zip:430000
TECHNIQUES SPECIFICATIONS
Physical specifications
Screen:5.4'' Display Screen
SuitableAdult & Child
Mode:pneumatically powered and electrically controlled system
Working Mode:Closed; Semi-Closed; Semi-Open
CircuitBreathing circuit integrated standards
Tube:4Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min
Trolley:Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Drawer unitONE drawer totally extractable
Technical Specifications:
Gas requirement:Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6 MPa.
safety valve<12.5 kPa
Respiratory Rate1~99bpm
Flow meterO2:0.1~10L/Min, N2O:0.1~10L/Min
oxygen concentration in the mixed gas N2O/O2 > 21%
Oxygen Flush:25~75 L/min
modes of ventilationA/C, IPPV, SIPPV, IMV, SIMV, MANUAL
I/E Ratio:4:1 ~ 1:10, Has the inverse ratio ventilation
Tidal Volume0~1500ML
ptr inspiratory triggering pressure-0.1kPa~1.0kPa
Inspiratory Plateau:0~1s
O2 Concentration:21%~100%
Maximum safety pressure:≤ 12.5 kPa
Pressure limit range:0 ~ 6.0 kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa
±0.2 kPa
Tidal volume alarm: Audible and visual and with yellow and red color indicatingupper alarm: 50 to 2000ml, lower alarm: 0~1800ml
Power Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature:10 ~ 40oC
Relative humidity:no higher than 80 %
Atmospheric pressure:860 hPa ~ 1060 hPa