Model:HG-SP
Heat pipe split solar water heater /Separated pressure solar water heater /Separated Pressurized System
1)When the temperature of heat collector reaches the set value ,the controller will make the circulation pump work automatically
2)The circulation pump makes heat-conducting liquid circulate automatically.
3) The heat-conducting liquid transfers heat to water by the heat exchanger in the tank .
4)In case the temperature of the circulation pump does not reach the set value ,the circulation pump will be shut automatically.
5)In case the temperature of the tank does not reach maximum temperature ,then start the auxiliary heating device .
The separated pressurized solar water heater composed by heat controller,storage tank,controller working station and installtion parts.
Specification: | |||
Model number: | HG-SP | Vacuum tube heat | D58*L1800MM / D70*L2000MM With straight copper heat pipe |
Inner tank material & thickness | imported SUS304 stainless steel 1.2-2.0mm | Bracket material l& thickness | Aluminum alloy 1.8mm |
Outer tank material & thickness | Galvanized steel 0.4mm .0.5mm | Heat insulating layer material & thickness | imported polyurethane foam 50mm |
Tube hail resistance | ≤25mm | Cold resistance | 40 |
Watering temperature | 99 | Stagnation temperature | 300 |
Watering pressure | 1.0Mpa (10bar) | Capacity | 150,200,250,300,400,500L |