Metallurgy, Mineral & Energy
Air Driven Gas Booster -STA 25
2016-10-31 03:51  Views:41
Price:Negotiable
Send Inquiry

  • Air driven gas boosters including STA25 are high pressure reciprocating pumps used for gases boosting,driven of compressed shop air. STA Series boosters are single acting, single air head driven type.(Except Model STA02 and STA05.They are double acting models).They have to be prepressurized at the inlet port so as to meet with the outlet pressure requirements,which value will be variable based on the permitted maximum outlet pressure. 
  • STA series gas boosters are suitable for the oil free compression of air and Industrial gases like Nitrogen, Helium as well as flammable and risk gases like hydrogen ,oxygen and natural gas.Air drive pressure from 1bar(14.5psi.) to 8bar(116psi.). Provide for operating pressures up to 80Mpa.       

                       

     

                    STA02 Model                                                                    STA25 Model

 

Key features 

  • Double action for effective operation (Model STA02 and STA05)
  • No electricity required. Safe operation, ex-proof
  • More appropriate ratios for meeting higher flowrates and faster fill times
  • No airline lubricator required
  • Hydrocarbon free-seperation between air drive and gas booster sections
  • Suitable for most gases
  • Built-in cooling
  • High quality seals, long life service available
  • All components in contact with the gas are made of aluminium or resp. stainless steel
  • Wide range of models. There are nine models for your option
  • Standard and custom systems available  

 

Applications

  • Mining,fire&safety
  • Aircraft ground support
  • Automotive air bag vessel filling
  • Power generation
  • Injection moulding
  • Accumulator charging
  • Supply for isolating gas systems
  • Gas proof testing
  • Hydrostatic and Burst Pressure testing for valves,pipes and tubing, pressure vessels and air craft components,etc.
  • Safety valve adjusting   

 

Technical parameters 

Type

Pressure

ratio

Min. gas

inlet

pressure

PA (bar)

Max.gas

inlet

pressure

PA (bar)

Max.gas

oulet

pressure

PB (bar)

Formula to

Calculate

gas oulet

pressure PB

Connection:

Gas Inlet /

Gas outlet

Max. flow at air

drive pressure of

6bar (L/min)

STA02

21

1.7

16

16

2X PL

ZG1/2/ ZG1/2

824(at PAof 6 bar )

STA05

51

3.5

40

40

5XPL

ZG1/2/ ZG1/2

380(at PAof 6 bar )

STA10

101

5.5

80

80

10XPL

ZG1/4/ ZG1/4

196(at PAof 20 bar )

STA25

251

10

200

200

25XPL

ZG1/4/ ZG1/4

81(at PA of 20 bar )

STA40

401

15

320

320

40XPL

ZG1/4/ ZG1/4

49(at PA of 20 bar )

STA60

601

25

480

480

60XPL

ZG1/4/ ZG1/4

61(at PAof 40 bar )

STA100

1001

35

800

800

100XPL

ZG1/4/ ZG1/4

39(at PA of 40 bar )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:  PL: air drive pressure   PA: gas inlet pressure   PB: gas outlet pressure   

 

Please consult us for printable performance charts for STA series boosters sized to your specific application parameters.

 

Contact Infomation
Send Inquiry
Company name:Jinan Shineeast Fluid Systems Equipment CO.,LTD.
Status:[Offline] [Send message] [Chat]
Business contact:Karen Chang(Mr.)
Telphone:
Mobile:
Fax:
Area: Caribbean Region-Bermuda
Address:NO.182-27 North Industrial Road , Jinan City in Shandong