Features of plant,
- Fully low pressure process, molecular sieve purification, air expansion with booster
- Advanced design tools are applied i.e. process calculation and optimisation with process simulation program HYSYS
- Refrigerating unit for pre-cooling system for less land occupation and investment
- Advanced and reliable performance APG-13X molecular sieve is used for purification of feed air
- Turbo expander with booster for expansion of compressed air
- Lower column adopts high efficiency circumfluent sieve plate column for higher ratio of extraction
- Hydrogen-free technology for argon extraction
- PLC control for the air separation plant
Output of plant and specification of products,
- Oxygen
Oxygen output (cold box outlet) 1000 Nm3/h(gaseous form)
Oxygen purity (cold box outlet ) 99.6% O2
Oxygen pressure from cold box ~0.04MPa (G)
- Nitrogen
Nitrogen output (cold box outlet) 1000 Nm3/h(gaseous form)
Nitrogen purity (Cold box outlet) 99.99% N2
Nitrogen pressure from cold box ~0.01MPa (G)
- Liquid argon
Liquid argon output (Cold box outlet) 25 Nm3/h(transferred into gaseous form)
Liquid argon purity (Cold box outlet) 99.99% Ar
Liquid argon pressure from cold box ~0.02Mpa(G)(To liquid argon tank)