Brand:Polycarboxylate Superplasticizer (Powder)
MOQ:10
Quantity:100
Uses
- JK-04 PP can be applied in a wide variety industry and canimprove the workability to the concrete and to improve high earlycompressive strength, even with low water/cement ratios whilemaintaining normal levels of workability.
- It can be widely used in conventional concrete, pumpingconcrete, super-fluid self-compacting and high-performanceconcrete; it has the excellent performance especially in theapplication of high-strength high performance concrete.
Advantage
- High water reducing rate and excellent plasticizing effect. Andproduces concrete with high levels of workability withoutsegregation.
- Excellent dispersion and self-compacting effect can producedifferent grade strength super fluid self-compacting concrete.
- Can be a substantial increase in early and late strengths ofconcrete, so that increase the project construction schedule.
- Better plasticity-maintaining could significantly prolong thetransit time of concrete, it reduce economic losses and ensure thenormal pumping of concrete.
- Improves the frost resistance and carbonation resistance of theconcrete. Lower drying shrinkage of the concrete by 20% or morecompared with naphthalene-based admixtures.
- High applicability: It can be used with different variety ofcement.
- Improved finished concrete surface ability.
- Proffer air environment protect.
- No chloride ions and no corrosion to steel bar.
Dosage
0.18– 0.22% by weight of cement. Standard water reduction atnormal dosage and significant water reduction at higher dosage.Exact dosage rates are dependent on the type of effect sought,quality of cement and aggregates, water/cement ratio and ambienttemperature. Therefore, in many cases it is advisable to carry outtrial mixes.
Specification
Items | Specification |
Appearance | Light Yellow Powder |
Solid Content (%) | 98.0±1.0 |
Density (23âÂ??Â??)(kg/m3) | 510±10 |
Chloride Content (%) | ≤0.10 |
Na2SO4 Content (%) | ≤4.0 |
Na2O 0.658K2O (%) | ≤5.0 |
Solubility | Excellent |
Cement Paste Flow | ≥240 |
Technical data sheet
Items | Specification | |
Water Reducing Rate % | ≥25 | |
Compressive Strength Ratio % | 1 day | ≥170 |
3 days | ≥160 | |
7 days | ≥150 | |
28 days | ≥130 | |
Air Content % | ≤6.0 | |
Bleeding Ratio % | ≤60 | |
Shrinkage (28 day) % | ≤100 | |
Setting Time difference min. | Initial | -90~ 120 |
Finally | ||
Chloride Penetration,Coulomb | ≤2000 | |
F/T Cycles, Time | ≥300 | |
Slump Retention (60min) mm | ≥150 | |
Cautions
- Cannot be added together with rosin soup air entrainer.
- Cannot be kept in metal container for too long.
- When mixing and measuring the slump loss, be aware that ittakes longer time to be in effect than naphthalene admixtures.
- Do not mix with naphthalene-based admixtures. If otheradmixtures, such as set retarder or corrosion-inhibiting admixture,are required simultaneously for some special projects,compatibility tests should be conducted beforehand.