Metallurgy, Mineral & Energy
Controllers Solar Water Heater Controllers (SR1168)
2016-11-06 13:35  Views:177
Price:Negotiable
Send Inquiry

2011 New Product! Data logging onto SD memory card! Internet access! 6 application system can be programmed! APPLICATIONS CAPACITY Max. Number of collectors: 2 Max. Number of storage tanks: 2 Max. Number of relays: 4 Max. Number of sensors: 5 Max. Number of application system: 8

TECHNICAL DATA
Dimension: 188mm x140mm x42mm
Power supply: 200V-240V AC or 100V-130V AC, 50-60Hz.
Power consumption: < 3W
Accuracy of temperature measuring: ± 2centigrade
Range of collector temperature measuring: -10centigrade -200centigrade
Range of tank temperature measuring: 0centigrade -110centigrade
Suitable power of pump: 4 pumps possible to be connected, power of each pump < 200W.
Inputs: 5 sensors,
2PCS*PT1000 sensor (≤ 500centigrade) for collector (silicon cable≤ 280centigrade),
3PCS*NTC10K, B3950 sensor (≤ 135centigrade) for tank, (PVC cable ≤ 105centigrade),
Outputs: 4 relays, for circulation pumps or 3-way electromagnetic valve
Ambient temperature: -10centigrade -50centigrade.
Water proof grade: IP40.

MAIN FUNCTIONS
Timing heating
Temperature difference control 2*Δ T
Collector emergency shutdown
Collector cooling function
Collector low temperature protection
Collector frost protection
Tank re-cooling function
Celsius and Fahrenheit transferring
Maximum temperature of tank (2*storage tanks)

Maximum turnoff temperature
(for solid fuel boiler, return heating, heat transferring between tanks)
Minimum turn-on temperature
(for solid fuel boiler, return heating, heating transferring between tanks)
Anti-Legionella function
Temperature controlled hot water circulation pump
Switch on/off temperature of solid fuel boiler( Independent of system)
RPM speed controlling(2*semiconductors)
Thermal energy measuring
Priority logic of multiple-tanks( 2*storage tanks)
Pump interval function
Thermostat function( Independent of system)

High temperature by-pass function(Collector cooling down)
Solar circulation Bypass
Data logging onto SD memory card
Internet access
Manual Control( for 4 outputs: P1, P2, R1, H1)
Password setting
Recovery to factory setting
Holiday function
Manual Heating
Temperature query function
Memory Protection
Screen protection
Trouble shooting
Trouble protection
Trouble checking

Contact Infomation
Send Inquiry
Company name:Ultisolar New Energy Co., Ltd.
Status:[Offline] [Send message] [Chat]
Business contact:Zhang Woolf(Mr.)
Telphone:
Area: Caribbean Region-Bermuda
Address:Wujin District, Changzhou, Jiangsu, China