Price:Negotiable
Brand:SUNDY
MOQ:1
Quantity:300
Send Inquiry
Bomb CalorimeterSDC311a
Applicable Scope:
SDC Series Calorimeters are applicable to measure the calorificvalue of coal, coke, petroleum, cement black meal and othercombustibles.
Applicable standards
ASTM D 5865-2007a Standard Test Methodfor Gross Calorific Value of Coal and Coke
GB/T213-2008 Determinationof calorific value of coal
Standard layout: SDC311a mainframe, Lenovocomputer, Laser printer
Technicalparameter:
Single Complete Testing Duration | <11 min | Precision | RSD≤0.1% |
Stability | Heat Capacity Variation in 3 months≤0.20 % | Ambient Temperature | The test results confirm to demands whentemperature during (10-30)oC |
Accuracy | The mean value and standard value deviation is less than 50J/gafter 5 caloric value tests of benzoic acid. | Max Test Range | 42000J/g |
Temperature Resolution | 0.0001 K | Sample Weight | 0.5-1.5g |
the Water Weight of External Barrel | 40kg | New type of Oxygen Bomb | Yes |
Oxygen Bomb Identification | Automatic | CAN Bus Interface | Yes |
Self-diagnostic Function | Yes | Complete Appliance Crust Shaped | Yes |
Max Power | 1.5kW | Voltage | AC220±10% 50Hz±1Hz |
Mainframe Size | 432×560×393mm | Net Weight | 60kg |
Main Features :Fast testing speed , large increaseof the testing efficiency , the complete testing duration <11min, the single equipment testing 4~6 times /h.All measureddata is real and reliable , without the use of the softwarecorrection to change the testing results . Highly environmentadaptable, the air flow and fluctuation of the ambient temperature(e.g. whether it is close to the heat source , large fluctuation ofthe ambient temperature, etc) will not affect theaccuracy and stability of the test. Compact size andstructure , attractive appearance, with the use ofquite a lot mould making and smallest test table-board is required. Simple erection and debugging, with no externalhardware co
ntrol or complicated mechanical compo
nents so as toensure stable operation of the instrument . New type of oxygenbomb, automatic identification of the oxygen bomb, automaticutilization of the built-in volume measurement unit to fix theinner barrel water volume , automatic co
ntrol of the watertemperature of the inner and external barrels, automaticimplementation of the whole testprocess. Application of the advanced communicatio
ncontrol technique. The CAN bus interface realized multipleco
ntrol with one computer , and the inter-testingactivity will not affect each other ( different models anddifferent kinds of the equipment ).
High Automation Vertical Bomb Calorimeter